Jiangsu OJi Paper Co.
Publishdate:2023-06-10 Views:45
|
|
200t/h circulating fluidized bed boiler denitrification project
Flue gas operating conditions for SCR denitrification units:
Flue gas volume:201000Nm³/h;
Operating temperature:170-190℃;
Process route:CFB furnace desulfurization + bag filter + SGH + GGH hot air furnace + low temperature SCR denitrification + GGH + wet desulfurization |
200t/h循环流化床锅炉脱硝项目
SCR脱硝装置烟气运行条件:
烟气量:201000Nm³/h;
运行温度:170-190℃;
工艺路线:CFB炉内脱硫+布袋除尘+SGH+GGH热风炉+低温SCR脱硝+GGH+湿法脱硫